GMR-32B three-phase surge protector
Jul 27, 2013   Tag: Stabilized voltage supply, the easy thing is special,

Contact Information
Contacts: Engineer Li
Mobile Phone: 86 15901631703
Address: Fengxian district Nanqiao Town of Shanghai Shanghai Shanghai presents Pu Long of main road 95 with respect
Telephone: 86-021-60640260
Fax: 86-021-61240084

 

Our company supplies GMR-32B three-phase surge protector of the power, battery, quality assurance, welcome to negotiate.

Three-phase surge protector, phase sequence protector, pass the voltage shortage protector, apply to air compressor, electric motor, distribution box, water pump, oil pump, central air conditioning unit, electric cabinet, switch board, hoist etc. extensively, the for instance central compressor of air conditioner is protected, the power protection of different lifts, water pump, oil pump prevent open phase, anti-phase from protecting etc., the vital protection products of the maintenance equipment with normal working voltage in it is that the commercial installation is operated
GMR serial multi-functional surge protectors (also called phase sequence protector of the three-phase power, passing the voltage shortage protector,etc.)
Used mainly for exchanging 50/60Hz, under the nominal voltage 460V, various fault detection in voltage ranks such as industrial three-phase 220V, 380V, 440V, 460V,etc., the overtension, voltage of inputting the power to three phases are overlow, open phase, anti-phase (phase sequence) , relay protection of offering such as the three-phase voltage imbalance, voltage unbalance.
Three-phase surge protector, phase sequence protector, passing the voltage shortage protector,
GMR-32B GMR-52B GMR-52B1F
GMR-32B1 GMR-22A GMR-32
GMR-32B3 GMR-32BD GMR-32BL
GMR-32BH GMR-32BT GMR-YK-32B
GMPR-ZT GMPR-IT GMPR-AT
GMPR-ZS GMPR-IS GMPR-AS
GMPR-NT GMPR-NS
Mainly deal in the products:
The intersection of Mitsubishi and the whole series of products / Panasonic / servomotor, general Fez / the intersection of sea and man-machine Tyke,etc. / touch-sensitive screen, Siemens, overtime Luo of fitting Sichuan etc.
ABJ1 series brief introduction is as follows, according to different type protection functions Excess voltage protection. Owe voltage protection. Phase sequence is protected. Dynamic phase-failure protection. Static phase-failure protection. The voltage imbalance, voltage unbalance is protected.
Have, delay time, protect the function while being X-type ' The time of time delay is not greater than 3 seconds) This protective relay design concept is novel. Reliable performance, the ability to resist voltage fluctuation is strong, it is convenient and reliable to install the interstar connection, the clear display of the trouble
ABJ1-14WAX ABJ1-12
ABJ1-14CY ABJ1-18AH ABJ1-14FP
Three-phase surge protector, phase sequence protector, passing the voltage shortage protector
ABJ1-10W three-phase alternating current protective relay
ABJ1-12W three-phase alternating current protective relay
ABJ1-14W three-phase alternating current protective relay
ABJ1-14WFX three-phase alternating current protective relay
ABJ1-14WBX three-phase alternating current protective relay
The tape supports the protective three-phase surge protector
ABJ1-122 three-phase alternating current protective relay
ABJ1-14FY three-phase alternating current protective relay
ABJ1-18AY three-phase alternating current protective relay
ABJ1-19AH three-phase alternating current monitors and the protective relay
ABJ1-18DY but regulating type three-phase alternating current protective relay
Product introduction ~~
First, ABJ1-10W The protective relay of three-phase alternating current is miniature
Product function: The error phase protects the nominal voltage of the working power: 380VAC is in conformity with time: 1S Rated operational voltage: 240VAC, 24VDC rated operational current: 1A(AC-14,DC-13)
Second, ABJ1-12W three-phase alternating current protective relay
Product function: Error phase protect, interrupt dynamically, the intersection of static behavior and interrupt, nominal voltage of working power of voltage imbalance, voltage unbalance: 380VAC The voltage no the balanced ratio is presumed: 8% response time: 2S rated operational voltage: 240VAC,24VDC Rated operational current: 1A(AC-14,DC-13)
Third, ABJ1-14WFX The protective relay of three-phase alternating current is miniature Product function: Interrupt dynamically, the intersection of static behavior and interrupt, voltage imbalance, voltage unbalance, error phase, over voltage, owing voltage protection, the nominal voltage of the working power: 380VAC voltage no the balanced ratio is presumed: 8% Over voltage: 428VAC is under voltage: 332VAC response time: 3S rated operational voltage: 240VAC,24VDC Rated operational current: 1A(AC-14,DC-13)
Fourth, ABJ1-14WBX three-phase alternating current protective relay
Product function: Interrupt dynamically, the intersection of static behavior and interrupt, voltage imbalance, voltage unbalance, error phase, over voltage, owing voltage protection, the nominal voltage of the working power: 380VAC voltage no the balanced ratio is presumed: 8% Over voltage: 437VAC is under voltage: 323VAC guard delay: 3S rated operational voltage: 240VAC,24VDC Rated operational current: 1A(AC-14,DC-13)
Fifth, ABJ1-14FY takes load to protect the protective relay of three-phase alternating current
Product function: Interrupt dynamically, the intersection of static behavior and interrupt, voltage imbalance, voltage unbalance, error phase, overvoltage, low-voltage protection. The nominal voltage of the working power: 380VAC The voltage no the balanced ratio is presumed: 8% of the overvoltage protection is presumed: 428VAC low-voltage protection presumed: 332VAC response time: 5S resumes delaying time: 5Min The form of getting an electric shock: 2C rated operational voltage ( Contact) : 240VAC, 24VDC rated operational current (contact) : 1A(AC-14,DC-13)
Sixth, the intersection of ABJ1-18DY and strip supports protection but regulating type three-phase alternating current protective relay This type has interrupting and voltage imbalance, voltage unbalance of two set that monitors the sensor to monitor the contact of the AC contactor. It is a unique invention patented product of our company that this monitors the way. The intersection of ABJ1-18DY and type apply Dalian to already refrigerator Co., Ltd. and Wuhan the intersection of MacVeagh and the intersection of cooler air-conditioner and the intersection of Co., Ltd.,etc. and five year such as protection control system such as compressor so as to Have, accident-free to take place, have reliability to be fine monitoring a great deal of advantages such as being overall.
Product function: Interrupt dynamically, the intersection of static behavior and interrupt, voltage imbalance, voltage unbalance, error phase, overvoltage, low-voltage protection. A, b, c function: Interrupt dynamically, loss of phase of static behavior, voltage imbalance, voltage unbalance protection. The nominal voltage of the working power: 380VAC voltage no the balanced ratio is presumed: 8% of the overvoltage protection is presumed: 420VAC Low-voltage protection is presumed: 340VAC response time: 5S resumes delaying time: 5Min rated operational voltage ( Contact) : 240VAC,24VDC Rated operational current ( Contact) : 1A(AC-14,DC-13)
Seventh, ABJ1-18AY Take load to protect the protective relay of three-phase alternating current Product function: Interrupt dynamically, the intersection of static behavior and interrupt, voltage imbalance, voltage unbalance, error phase, overvoltage, low-voltage protection. Nominal voltage: 380VAC work pressed: 380VAC 20% The voltage no the balanced ratio is presumed: 8% of the overvoltage protection is presumed: 420VAC low-voltage protection presumed: 340VAC protects and delays time: 5S phase-failure protection delays time: 1S resumes delaying time: 5Min Rated operational voltage ( Contact) : 240VAC, 24VDC rated operational current (contact) : 1A(AC-14,DC-13)
Eighth, ABJ1-19AH tape support the protective three-phase alternating current monitoring and protective relay
Product function: Interrupt dynamically, static behavior interrupt and voltage imbalance, voltage unbalance, error phase, overvoltage, voltage shortage monitor. Ambient temperature: -25oC is +55oC relative humidity: < Nominal voltage 90%: 380VAC 20% 50~60HZ The voltage no the balanced ratio is presumed: < 8% of the overvoltage protection is presumed: 420VAC low-voltage protection presumed: 340VAC protects and delays time: 5S 20% Resume delaying time: 5Min 20% rated operational voltage (contact) : 250VAC,28VDC Rated operational current ( Contact) : 1A(AC-14,DC-13)
Ninth, ABJ1-122 takes load to protect the protective relay of three-phase alternating current
Product function: Interrupt dynamically, static behavior interrupt and voltage imbalance, voltage unbalance, error phase protect the nominal voltage of the working power: 380VAC The voltage no the balanced ratio is presumed: 8% response time: 2S form of getting an electric shock: 2C rated operational voltage ( Contact) : 240VAC,24VDC Rated operational current ( Contact) : 1A(AC-14,DC-13)

 